By pushing the button down, a ring lowers itself into the soap solution, creating a perfect film. Releasing the button lifts the film to the flow tube automatically.
Built-in infrared bubble sensors This feature senses when the bubble passes the lower sensor, then the upper sensor. The electronics then calculate the flow rate of the bubble and indicate the reading on the LCD display. Interchangeable flow cells The new Gilibrator system is an easy-to-use primary flow calibrator. This allows the user to buy one unit and simply switch the flow cell chamber for a specific calibration range.
Flow cell ranges include a high flow of LPM to calibrate large scale high volume samplers. A standard range will cover most of your flow equipment ranges from 20cc-6LPM.
Pulsation dampers The pulsation damper removes pulsation from the flow source for higher accuracy sampling as well as eliminating pulsations back into the flow source during bubble generation. Average, delete, and reset functions Successive readings can be taken and the Gilibrator will automatically average the readings taken during that trial.
If an error is made due to an improper bubble, that reading may be deleted from the average and brought back to the previous average. To reset the system, which initiates a new averaging sequence, simply press Reset. This will prevent you from inadvertently initiating another bubble during the run. The charge LED indicates that the battery is being charged. Rechargeable battery system This enables you to use the Gilibrator anywhere, in the lab or in the field.
When fully charged, the Gilibrator will operate for a period of eight hours The unit can also be used on AC current. The MultiRAE Series of handheld gas detectors includes three models for detection of up to six threats simultaneously. Choose from 25 toxic sensors, 3 PID sensors with a 9. The Professional Plus is the world's most versatile water quality meter. Interchangeable cables and multiple accessories allow a single instrument to be quickly changed for use in the field as a handheld meter, for low flow sampling, or in the laboratory.
When the button is upper and lower chamber of the bubble generator, is released, the ring lifts out of the soap solution and a the Sensor Block refer to Figure 2. If this happens, your flow cell Flow Cell should mount flush with the Mounting needs to be returned to Sensidyne to be upgraded. See Plate. Appendix C page 30 for more information. If alignment is correct, the Cell Assembly bottom should mount flush with the Mounting Plate. Continue to add When this button is pressed for less than 1 second, a negative symbol appears on the Control Unit display.
Page Storage You should also return the unit to the factory annually Turn Off the Control Unit, the sampling source, and for calibration.
Contact the Sensidyne Service Depart- any attached output devices if applicable. Painted aluminum sheet metal Unit Orientation Base: Horizontal, on flat surface Controls These options include initial training, on-site technical assistance, and full factory repairs.